LXLC-50E~250E Horizontal Woltman Type Water Meter |
| |
 |
| |
| Product Information |
| |
| Application,Features: |
Measuring the volume of cold potable water passing through the pipeline.
The measuring element is exchangeable with LXL type¡¯s,More advantages as follows: Magnetic coupling.Small transmission resistance,non-leakage after shaft wear,reliable register structure,easy reading,nice looking stc.
|
Working Condition: |
Water temperature: ≤40ºC for
Water pressure: ≤1Mpa
Maximum Permissible Error:
a) In the lower zone from Qmin inclusive up to but excluding Qt is ±5%
b) In the upper zone from Qt inclusive up to and inclding Qs is ±2% |
| Main Technical Data: |
|
|
Type
|
Size mm
|
Class
|
qs Max Flow |
qp Nominal flow |
qt Transitional flow |
qmin Min. Flow |
Min. Reading |
Max Rreading |
Length L |
|
|
Weight Kg |
|
m3/h |
m3 |
mm |
Outer Dia mm(D) |
Bolt Circle Dia mm(D1) |
Connecting Bolt (Pcs) |
|
LXLC-50E |
50 |
A |
30 |
15 |
4.5 |
1.2 |
0.001 |
999999 |
200 |
175 |
165 |
125 |
4*M16 |
8.5 |
|
B |
3.0 |
0.45 |
|
LXLC-80E |
80 |
A |
80 |
40 |
12 |
3.2 |
0.001 |
999999 |
225 |
225 |
200 |
160 |
8*M16 |
13.5 |
|
B |
8.0 |
1.2 |
|
LXLC-100E |
100 |
A |
120 |
60 |
18 |
4.8 |
0.001 |
999999 |
250 |
235 |
220 |
180 |
8*M16 |
15.5 |
|
B |
12 |
1.8 |
|
LXLC-150E |
150 |
A |
300 |
150 |
45 |
12 |
0.001 |
999999 |
300 |
331 |
285 |
240 |
8*M20 |
27 |
|
B |
30 |
4.5 |
|
LXLC-200E |
200 |
A |
500 |
250 |
75 |
20 |
0.001 |
999999 |
350 |
338 |
340 |
295 |
8*M20 |
40.5 |
|
B |
50 |
7.5 |
|
LXLC-250E |
250 |
A |
800 |
400 |
120 |
32 |
0.001 |
999999 |
400 |
400 |
395 |
350 |
12*M20 |
56 |
|
B |
80 |
12 |
|
|
| |
|
Dimensions and Weight |
 |
|
Pressure Loss Curve |
 |
|
| |
| |
| |
| |
| |
| |
| |
|
| |
| |
|